3:41 The challenge
- →Horizontal coal-seam-gas well pairs require precise toe-to-toe intercepts.
- →Accumulated MWD survey error produces lateral shifts exceeding 10 m in some instances.
- →Undetected, these shifts cause missed intercepts and lost hydraulic communication.
- →Intercept requires the wellbores to physically intersect — not statistically achievable on MWD alone, so ranging must guide the approach.
Our solution
Torped™ rotating-magnet ranging: magnets integrated into the directional rotary-steerable BHA, with the sensor run on wireline in the target well. A shift-vector methodology resolved true relative position at each station and steered every intercept. Delivered alongside major directional-drilling partners.
5 of 5 intercepts successful · 4 jobs to date · 0.128 m final centre-to-centre
The result
5 intercepts
across 3 well pairs, 100% success
- ·All 5 planned intercepts achieved across 4 jobs to date
- ·Best result 0.128 m centre-to-centre, inside the 7-in. GRE-cased window
- ·Detection at 71–78 m; per-shot uncertainty narrowed from 7.8% to 0.3–0.8%
- ·Detected and corrected real lateral shifts exceeding 10 m
Ranging
AMR (Torped™)
Deployment
BHA While Drilling
Re-entry
Yes
Location
Queensland, Australia
Year
2025 – ongoing
Watch, related footage
Full video library →
3:41
3:24